Skip to content

Services

Seven services that take a project from the first survey to a verified installation.

Lighting survey and audit

A measured record of the lighting you have now: what is installed, how much light it delivers, how long it runs and what it costs.

You receive

  • Survey report with marked-up plans and measured lux levels
  • Asset schedule of existing fittings
  • List of areas that are under-lit, over-lit or non-compliant
  • Baseline energy figure for comparing options

Lighting design and calculation

A calculated scheme for each space: where every luminaire goes, what it delivers, and evidence that it meets the standard.

You receive

  • Calculation report with illuminance plots and results tables
  • Lighting layout drawings in DWG and PDF
  • Luminaire schedule with quantities, wattage and mounting details
  • Statement of compliance against the agreed criteria

Emergency lighting design

Escape lighting that works when the supply fails, designed to the standard and documented so that it can be tested.

You receive

  • Emergency lighting layout drawings
  • Calculation report for escape routes and open areas
  • Luminaire and signage schedule
  • Completion certificate and logbook in the BS 5266-1 format

Lighting controls design

A written strategy for when each luminaire is on, off or dimmed, so that the installation uses energy only when and where light is needed.

You receive

  • Controls strategy document and zoning drawings
  • Schedule of sensors, switches and control devices
  • Commissioning settings: time-outs, daylight set-points and scenes
  • User guide for the facilities team

Energy and payback appraisal

The financial case for the scheme: what it costs, what it saves and when it pays back.

You receive

  • Appraisal report with simple payback and whole-life cost
  • Option comparison table
  • Supporting figures for funding applications or energy reporting

Luminaire and controls supply

We supply the luminaires, emergency fittings and controls that we specify, so the products on site are the products in the calculation.

You receive

  • Fixed supply price against the luminaire schedule
  • Delivery schedule
  • Product data sheets, declarations of conformity and warranty documents
  • Operation and maintenance information for the handover file

Commissioning and verification

Checks on site that the installed lighting performs as designed, with the measurements to show it.

You receive

  • Commissioning report comparing measured and designed illuminance
  • Record drawings and final luminaire schedule
  • Record of controls settings
  • Emergency lighting completion certificate and logbook