Skip to content

Education

Classrooms are used for reading, writing, screens and presentation within the same hour. The lighting has to serve all of them and be simple enough that teachers use the controls.

What decides the design

The board as well as the desks
The whiteboard or display wall needs its own vertical illuminance and must be free of reflections from the front row of luminaires.
Daylight first
Most classrooms have good daylight. Rows of luminaires parallel to the windows should dim independently of each other.
Simple scenes
A small number of clearly labelled settings works better than a full control panel.
Robustness
Sports halls, corridors and workshops need impact-resistant fittings and a higher ingress protection rating.

Light levels

300 lux in classrooms, 500 lux at the board. The full list for this sector:

Education: requirements from BS EN 12464-1:2011
Task or areaLuxUGR limitUniformityRa
Classrooms, tutorial rooms300190.6080
Classrooms for evening classes and adult education500190.6080
Black, green and white boards500190.7080
Lecture halls500190.6080
Circulation areas, corridors100250.4080
Stairs150250.4080

Later editions of the standard revise some values. How to read these figures

What we usually do here

Next: Warehousing and logistics